Light Commercial
High Static Blower Drive Kits
6 - 15 Ton Light Commercial Package System
INSTALLATION INSTRUCTIONS
WARNING:
ELECTRICAL SHOCK, FIRE OR EXPLOSION
HAZARD
Failure to follow safety warnings exactly could result
in serious injury or property damage.
Improper installation or servicing could result
in dangerous operation, serious injury, death or
property damage.
Before servicing, disconnect all electrical power
to the unit.
When servicing controls, label all wires prior to
disconnecting. Reconnect wires correctly.
Verify proper operation after servicing.
KIT # 918799 918800 920394 920395 920396 920558 920559 920606
Motor X X XXXXX
Ext. Motor Overload X
Overload Adapter X
Motor Sheave X X XXXXX
Blower Pulley X X X XXXXX
Drive Belt X X X XXXXX
Overload Wires X X XXXXX
Parts Kit XXXXXXXX
KIT # 920607 920608 920609 920613 920618 920560 920637
Motor X X XXXXX
Ext. Motor Overload X X X X X
Overload Adapter X X X X X
Motor Sheave X XXXXX
Blower Pulley X X XXXXX
Drive Belt X X XXXXX
Overload Wires X X XXXXX
Parts Kit XXXXXXX
NOTE TO INSTALLER: The blower drive kits listed in Table 1 are
applicable only to NORDYNE units equipped with NORDYNE
motors. The use of these kits with non-NORDYNE motors may
not produce the same values shown in the airfl ow tables or
other data provided.
Table 1. Blower Drive Kit Contents & Part Numbers
GENERAL
These instructions are primarily intended to assist qualifi ed individuals experienced in the proper installation of heating and/
or air conditioning appliances. Some local codes require licensed installation/service personnel for this type equipment and
their accessories. All installations must be in accordance with these instructions and with all applicable national and local
codes and standards. Please read all instructions thoroughly before installing the kit.
WARNING:
Improper installation, service, adjustment, or
maintenance can cause fi re, electrical shock, or
other conditions which may result in personal
injury or property damage. Unless otherwise noted
in these instructions, only factory authorized kits,
parts or accessories may be used when modifying
this equipment.
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - WARNING:

Light CommercialHigh Static Blower Drive Kits6 - 15 Ton Light Commercial Package SystemINSTALLATION INSTRUCTIONS WARNING:ELECTRICAL SHOCK, FIRE OR EXP

Pagina 2 - TABLE OF CONTENTS

10EXCERPTS FROM NEC 2005 HANDBOOK - BASED ON NFPA 70Partial Table 310.16 Allowable Ampacities of Insulated Conductors (0-2000 Volts) - Not more then 3

Pagina 3 - KIT APPLICATIONS

11P6SP-072*MSD kits:920609 (208-230V, 3Ø, 60 Hz)920560 (460V, 3Ø, 60 Hz)Downfl ow Performance Chart‡ Indicates Factory Sheave Setting for Pre-confi gure

Pagina 4 - INSTALLATION METHOD

12P6SP-072*MSD kits:920609 (208-230V, 3Ø, 60 Hz)920560 (460V, 3Ø, 60 Hz)Horizontal Flow Performance Chart*‡ Indicates Factory Sheave Setting for Pre-c

Pagina 5 - EXTERNAL MOTOR OVERLOADS

13P6SP-090*MSD kits:920607 (208-230V, 3Ø, 60 Hz)920606 (460V, 3Ø, 60 Hz)Downfl ow Performance Chart‡ Indicates Factory Sheave Setting for Pre-confi gure

Pagina 6

14P6SP-090*MSD kits:920607 (208-230V, 3Ø, 60 Hz)920606 (460V, 3Ø, 60 Hz)Horizontal Flow Performance Chart*‡ Indicates Factory Sheave Setting for Pre-c

Pagina 7 - CAUTION:

15R6GP-072*-100CMSD kits:920609 (208-230V, 3Ø, 60 Hz)920560 (460V, 3Ø, 60 Hz)Downfl ow Performance Chart‡ Indicates Factory Sheave Setting for Pre-confi

Pagina 8

16R6GP-072*-100CMSD kits:920609 (208-230V, 3Ø, 60 Hz)920560 (460V, 3Ø, 60 Hz)Horizontal Flow Performance Chart*‡ Indicates Factory Sheave Setting for

Pagina 9

17R6GP-072*-166CMSD kits:920609 (208-230V, 3Ø, 60 Hz)920560 (460V, 3Ø, 60 Hz)Downfl ow Performance Chart‡ Indicates Factory Sheave Setting for Pre-confi

Pagina 10 - Uncoated Copper Wire Only

18R6GP-072*-166CMSD kits:920613 (208-230V, 3Ø, 60 Hz)920618 (460V, 3Ø, 60 Hz)Horizontal Flow Performance Chart*‡ Indicates Factory Sheave Setting for

Pagina 11

19R6GP-090*-200CMSD kits:920607 (208-230V, 3Ø, 60 Hz)920606 (460V, 3Ø, 60 Hz)Downfl ow Performance Chart‡ Indicates Factory Sheave Setting for Pre-confi

Pagina 12

2Kit Applications ...3Pre-Installation Information ...

Pagina 13

20R6GP-090*-200CMSD kits:920607 (208-230V, 3Ø, 60 Hz)920606 (460V, 3Ø, 60 Hz)Horizontal Flow Performance Chart*‡ Indicates Factory Sheave Setting for

Pagina 14

21P6SP-090*HSD kits:920559 (208-230V, 3Ø, 60 Hz)920558 (460V, 3Ø, 60 Hz)Downfl ow Performance Chart‡ Indicates Factory Sheave Setting for Pre-confi gure

Pagina 15

22P6SP-090*HSD kits:920559 (208-230V, 3Ø, 60 Hz)920558 (460V, 3Ø, 60 Hz)Horizontal Flow Performance Chart*‡ Indicates Factory Sheave Setting for Pre-c

Pagina 16

23P6SP-120* & Q6SP-120* & Q5SN-120*HSD kits:920396 (460V, 3Ø, 60 Hz)920395 (208-230V, 3Ø, 60 Hz)Downfl ow Performance Chart‡ Indicates Factory

Pagina 17

24P6SP-120* & Q6SP-120* & Q5SN-120*HSD kits:920395 (208-230V, 3Ø, 60 Hz)920396 (460V, 3Ø, 60 Hz)Horizontal Flow Performance Chart*‡ Indicates

Pagina 18

25Q6SP-090* & Q5SN-090*HSD kits920394 (208-230V, 3Ø, 60 Hz)920608 (460V, 3Ø, 60 Hz)Downfl ow Performance Chart‡ Indicates Factory Sheave Setting fo

Pagina 19

26Q6SP-090* & Q5SN-090*HSD kits:920394 (208-230V, 3Ø, 60 Hz)920608 (460V, 3Ø, 60 Hz)Horizontal Flow Performance Chart*‡ Indicates Factory Sheave S

Pagina 20

27R4GM & R6GN-150* SeriesHSD kits:918799 (208-230V, 3Ø, 60 Hz)920637 (460V, 3Ø, 60 Hz)Blower Performance Chart‡ Indicates Factory Sheave Setting f

Pagina 21

28R4GM & R6GN-180* SeriesHSD kits:918800 (208-230/460V, 3Ø, 60 Hz)Blower Performance Chart‡ Indicates Factory Sheave Setting for Pre-confi gured Un

Pagina 22

29R6GP-090*-200CHSD kits:920559 (208-230V, 3Ø, 60 Hz)920558 (460V, 3Ø, 60 Hz)Downfl ow Performance Chart‡ Indicates Factory Sheave Setting for Pre-confi

Pagina 23

3KIT APPLICATIONSPrior to installing a high static drive kit (HSDK), always review these installation instructions to ensure the proper application of

Pagina 24

30R6GP-090*-200CHSD kits:920559 (208-230V, 3Ø, 60 Hz)920558 (460V, 3Ø, 60 Hz)Horizontal Flow Performance Chart*‡ Indicates Factory Sheave Setting for

Pagina 25

31R6GP-120*-235CHSD kits:920395 (208-230V, 3Ø, 60 Hz)920396 (460V, 3Ø, 60 Hz)Downfl ow Performance Chart‡ Indicates Factory Sheave Setting for Pre-confi

Pagina 26

32R6GP-120*-235CHSD kits:920395 (208-230V, 3Ø, 60 Hz)920396 (460V, 3Ø, 60 Hz)Horizontal Flow Performance Chart*‡ Indicates Factory Sheave Setting for

Pagina 27

33UNITMODELGASTYPEHEATINGINPUTHEATINGOUTPUTHEATINGRISERANGECFM RANGESCFM 1950 2100 2250 2400 2550 2700R6GP-072*-100CNatural Gas 100,000 80,00015 - 45R

Pagina 28

34123On Drive Kits (for P6SP Series Units) that require the addition of an external overload relay.A) Use the included 97” wires to route power from t

Pagina 30

7088000 (Replaces 708435A)Specifi cations & illustrations subject to change without notice or incurring obligations.O’ Fallon, MO | Printed in U.S.

Pagina 31

4PRE-INSTALLATION INFORMATION & INSTALLATION METHODBefore You BeginIt is recommended that prior to a kit selection for a retrofi t installation, t

Pagina 32

5 RANGE OF PROTECTION(AMPS)RELAY PARTNUMBERREQUIRED MOUNTING PLATE1.4 - 2.0 624728 6220321.8 - 2.5 624729 6220322.8 - 4.0 622034 6220323.5 - 5.0 62207

Pagina 33

6MOTOR SHEAVE / PULLEYS / BELT INSTALLATION & ADJUSTMENT WARNING:Never perform maintenance on energized or rotating equipment. Always disconnect e

Pagina 34 - P6SP Series - 072/090 Units

7Mounting Split Taper Bushings in Split Taper Bushed PulleysPre- Installation• Make sure the shaft, bushing barrel & bore, split taper pulley bor

Pagina 35

8Grounding WARNING:The unit cabinet must have an uninterrupted or unbroken electrical ground to minimize personal injury if an electrical fault should

Pagina 36 - ¢708800{¤

9Example:AB = 451VBC = 460VAC = 453V2. Determine the average voltage in the power supply.3. Determine the maximum deviation:4. Determine percent of vo