ESP LOW-E THERMASHEET INSULATION
PRODUCT CODES: 4EMEX
PRODUCT DIMENSIONS & DESCRIPTION*
Double sided scrimless aluminum foil laminated to polyethylene foam with 4” foil flange overlap.
WIDTH: 4’
LENGTH*: 125’
R-Value** : R-9 downward heat flow only***
PERM RATING: ASTM E-96 0.008
FLAME AND SMOKE: ASTM E-84 Flame spread <25 Smoke developed <50
EMITTANCE: 0.03
* Additional lengths are available upon request and approval by ESP, Inc.
**
. Specific R-values for specific applications can be obtained from Install Guide at www.low-e.com
or by contacting ESP, Inc. at 1-800-289-5693
*** W
(1/8” nominal thickness)
ASTM C-1371
SYSTEM R-VALUES FOR THESE INSTALLATION METHODS WERE CALCULATED USING DATA FROM THE ASHRAE
HANDBOOK OF FUNDAMENTALS
ith 1.5” airspace
Environmentally Safe Products, Inc.
313 W. Golden Ln. New Oxford, PA 17350
Toll Free: 1-800-289-5693 Fax: 717-624-7089
ThermaSheet Insulation
Reduces your carbon footprint.
E
S
P
®
Scan Code To
See Install Guide
copyright©espjul1.2012
Note: ESP THERMASHEET is designed for use as a roofing underlayment
primarily for clay tile and/or metal roofing systems.
NOTE: Do not allow product to become damp or wet while rolled in sealed bag
Do not set product directly on wet or uncured concrete.
®
WARNING: Although ESP LOW-E Insulation Products are all fire tested to ASTM and/or NFPA standards; it is
recommended that they or any insulation material should not be exposed to open flame or other
ignition sources of sufficient intensity during shipment, storage or installation.
CAUTION: Aluminum is an electrical conductor. Please use caution when working around electrical sources
including overhead power lines. Carefully inspect electrical junction boxes and check for frayed
wires before beginning installation
“R means resistance to heat flow. The higher the R-value, the greater the insulating power.” “To get the marked R-Value, it is essential that this insulation be
installed properly. If you do it yourself, get instructions and follow them carefully. Instructions do not come with this package.” To obtain installation instructions
visit www.low-e.com or call 1-800-289-5693. Like a radiant barrier, Low-E products also block 97% of radiant heat.
“ESP, Inc strives to provide the most accurate R-value data possible.
The R-values set forth in this document are the reflection of a
combination of industry standard testing and conscientious calculation.
However, these numbers, even within specific applications, can fluctuate
due to the multiple variables that influence R-value."
15.
YOUR EVERYDAY INSULATION SOLUTION
Comentarios a estos manuales